Ampac
Six Stage Reverse Osmosis System with Aquatec
Booster Pump

This Ampac Six Stage Reverse osmosis W/Booster
Pump drinking water system is a high capacity 36 to 100 GPD (gallon per
day) system designed for Homes with Low Pressure Feed, high usage, and
custom installations where the system will feed more than one faucet. It
is equipped with a Booster Pump (Silent) to raise the pressure from 0
PSI to 65 PSI. It can be also equipped with an optional high flow
delivery pump that greatly increases flow rate. The Ampac™ APRO6-P
features a TFC membrane, and is offered with an optional ultraviolet.
If
your feed water come from a well, then this is the ideal system for your
home.
Standard
Features:
-
Aquatec CDP6800 Pump for
up to 50GPD.
-
Aquatec CDP8800 Pump for
up to 100GPD.
-
10" Sediment Pre-Filter 5
M. Polypropylene.
-
10" KDF-GAC Pre-Filter
Cartridge.
-
10" Carbon Block
Pre-Filter.
-
TFC Membrane & Auto.
Shut-off Valve.
-
In-Line GAC Post-Filter.
-
3.2 Gallons Pressure Tank
With Ball Valve.
-
Standard Long Reach SS
Lead Free Faucet.
-
All Quality Color Coded
Tubing Included.
-
Feed Water Valve, and
Drain Valve.
-
Heavy Duty, Built-in
Check Valve.
-
Available 120V/60Hz, and
220V/50Hz.
-
Installation Manual,
Registration Card.
-
Price $ 379.95
|
Optional Features:
|

Water Quality Monitor
|
 |
 |
 |
|
Drain Saddle Valve |
Water Feed Adapter |
Tank Ball Valve |
|
 |
 |
 |
| Long Reach
(Prop 65) Chrome Faucet |
Water
Storage Tank |
Installation Manual & Warranty |
| |
CDP 6800 Series Low Flow
Booster Pump
 |
Distinguishing
Features
- Toughest, most durable pump on market

- Adjustable max. outlet psi (regardless of feed pressure)
- Expels trapped air (no more air locks)
- Can be mounted w/pump head up or down
- More flow at extremely low inlet pressures
- New motor venting system to remove moisture
- EMI/RFI electronic noise suppression
- 100% final performance tested.
|
Key Operating
Benefits
- Boosts pressure 40 to 120 psi (adjustable)
- Fixed pressure to 160 psi
- Up to 30,000+ operating hours
- Whisper quiet - less than 45 DBA
- Can run dry without damage
- Self-priming - 60" lift
- Low voltage (12-24V) for maximum safety
- Corrosion resistant exterior
- Continuous or intermittent operation
|
Technical
Specifications
OPERATION: The
6800 is designed to operate with a PSW
Tank Shut-Off Switch for hydro-pneumatic storage
systems. The PSW, when used with a typical under-counter
R.O. system, can be augmented with an ESO
Electronic Shut-Off Valve. It is also compatible with
most hydraulic shut-off valves. For counter-top systems,
Aquatec's TLC
Tank Level Control Switch Valve shut off feed water and
the pump when the product water storage tank is full.
POWER: Pumps operate with low energy (only 14 watts), low
voltage (12-24 volt) motors, powered with compatible
transformers with world wide primary voltages available (100 VAC,
120 VAC, 230 VAC). Transformers are optional and must be ordered
in addition to the pump.
MOUNTING PLATES: The "flexible or steel" base plates are
included at no extra cost. The "Universal" base plate P/N 51-104
is available optionally at additional cost.
FITTINGS: Built-in 1/4" John Guest half cartridge
fittings eliminate need for external fittings (unless elbows are
required); 1/4" Jaco straight, 1/4" Jaco elbow fittings, or 8mm
stem adapters for metric tubing are optionally available.
INSTALLATION: The location and positioning of the pump
may affect its' performance. Always consult the factory for
recommendations that will optimize your system.
6800
Performance Curves |
| |
CAP 8800 Series High Flow
Booster Pump
 |
Distinguishing
Features
- Toughest, most durable pump on market

- Adjustable max. outlet psi (regardless of feed pressure)
- Expels trapped air (no more air locks)
- Can be mounted w/pump head up or down
- More flow at extremely low inlet pressures
- EMI/RFI electronic noise suppression
- New motor venting system to remove moisture
- 100% final performance tested.
|
Key Operating
Benefits
- Boosts pressure 40 to 120 psi (adjustable)
- Used with membranes 50 to 100 GDP
- 15,000+ operating hours
- Quiet - less than 52 DBA
- Can run dry without damage
- Self-priming - 60" lift
- Low voltage (12-24V) for maximum safety
- Corrosion resistant exterior
|
Technical
Specifications
OPERATION: The
CDP 8800 is designed to operate with a PSW
Tank Shut-Off Switch for hydro-pneumatic storage
systems. The PSW when used with a typical under-counter R.O.
system, can be augmented with an ESO
Electronic Shut-Off Valve. It is also compatible with
most hydraulic shutoff valves. For counter-top systems,
Aquatec's TLC
Tank Level Control Switch Valve shut off feed water when
the product water storage tank is full. The AFR
Auto-Flush Valve is highly recommended for higher
production membranes requiring a CDP 8800, to ensure membrane
efficiency.
POWER: Pumps operate with safe, low energy (only 24
watts), low voltage (12-24 volt) motors, powered with compatible
transformers with world wide primary voltages available (100 VAC,
120 VAC, 230 VAC). Transformers are optional and must be ordered
in addition to the pump.
MOUNTING PLATES: The steel base plate is included at no
extra cost. The "Universal" base plate P/N 51-104 is optionally
available at no additional cost.
FITTINGS: Built-in 3/8" John Guest half cartridge
fittings eliminate need for external fittings (unless elbows are
required); Optional at no cost are 3/8" Jaco straight, 3/8" Jaco
elbow fittings, or 8mm stem adapters for metric tubing. The
location and positioning of the pump may affect its'
performance. Consult the factory for recommendations that will
optimize your system.
8800
Performance Curves |
CDP 8800 High Flow Booster Pump
Model 881X-132X-XX
Performance Curves

|